Operations Manual
BOD
ANALYST
Software That Makes BOD Testing
Easier, More Efficient, and More Accurate
Seitenansicht 0
1 2 3 4 5 6 ... 69 70

Inhaltsverzeichnis

Seite 1 - Operations Manual

Operations ManualBODANALYSTSoftware That Makes BOD TestingEasier, More Efficient, and More Accurate

Seite 2

SECTION 2 SAMPLES2.1 WHAT IS A "SAMPLE?"With YSI’s BOD Analyst software you can organize your work by sample. A sample is anythingfor which

Seite 3 - CONTENTS

Samples Section 2YSI Incorporated BOD Analyst for Windows Software 7In this example, there are two dilutions: 150ml and 275ml. This Sample is seeded

Seite 4

Samples Section 2YSI Incorporated BOD Analyst for Windows Software 8Dilution Setup: You can have up to 5 dilutions for any Sample. On the General Setu

Seite 5 - SECTION 1 INTRODUCTION

Samples Section 2YSI Incorporated BOD Analyst for Windows Software 9Quality Control: Used in the trending graph function to display Quality Control Li

Seite 6 - STARTING THE PROGRAM

Samples Section 2YSI Incorporated BOD Analyst for Windows Software 10You can find a detailed description of the abbreviation algorithm in the next sec

Seite 7 - 1.3 QUICK START GUIDE

SECTION 3 SEEDING SAMPLES3.1 WHY SEED?Seeding is necessary when there are not enough bacteria present in the sample. A small amountof seed material t

Seite 8

Seeding Samples Section 3YSI Incorporated BOD Analyst for Windows Software 12If you seed directly to the bottle, the amount of seed material in each b

Seite 9

SECTION 4 SAMPLE GROUPS4.1 WHAT IS A "SAMPLE GROUP"?A Sample Group is a set of samples. For brevity, we often refer to Sample Groups as sim

Seite 10 - SECTION 2 SAMPLES

Sample groups Section 4YSI Incorporated BOD Analyst for Windows Software 14NOTE: The dilution blank sample is automatically added when you build a bat

Seite 11 - 2.3 ADDING A NEW SAMPLE

SECTION 5 BATCHES5.1 WHAT IS A "BATCH?"A Batch is all initial DOs that are done on any one day, along with their corresponding final DOs.Bec

Seite 13 -

Batches Section 5YSI Incorporated BOD Analyst for Windows Software 16The Open Batch Form can also be used to delete a batch. Select the batch to be d

Seite 14 - 2.6 DELETING A SAMPLE

Batches Section 5YSI Incorporated BOD Analyst for Windows Software 175.4 WORKING WITH BATCHES5.4.1 STEPS TO BUILDING A BATCHAdd the samples for the ba

Seite 15 - SECTION 3 SEEDING SAMPLES

Batches Section 5YSI Incorporated BOD Analyst for Windows Software 185.4.5 IMPORT BATCHThis feature allows you to setup a batch by importing a text fi

Seite 16

Batches Section 5YSI Incorporated BOD Analyst for Windows Software 19dilution oxygen depletion, seed correction factor and BOD are calculated automati

Seite 17 - SECTION 4 SAMPLE GROUPS

Batches Section 5YSI Incorporated BOD Analyst for Windows Software 20Select the sample to add from the list and the number of dilutions and the diluti

Seite 18 - 4.5 EDITING A GROUP

Batches Section 5YSI Incorporated BOD Analyst for Windows Software 21Notes: Used for any miscellaneous notes for the entire batch.Bottle Notes: This f

Seite 19 - SECTION 5 BATCHES

Batches Section 5YSI Incorporated BOD Analyst for Windows Software 225.14 DELETING A BOTTLETo remove a bottle from a batch, click on therow header and

Seite 20 - 5.3 THE BUILD BATCH FORM

SECTION 6 TAKING INITIAL DO READINGS6.1 ENTERING BOTTLE NUMBERS6.1.1 USING THE YSI 5000/5100 DO INSTRUMENTJust after selecting Read / Initials from th

Seite 21 - WORKING WITH BATCHES

Taking Initial DO Readings Section 6YSI Incorporated BOD Analyst for Windows Software 24then press CONFIRM.To enter "4" for the last digit,

Seite 22 - 5.5 THE BENCH SHEET

Taking Initial DO Readings Section 6YSI Incorporated BOD Analyst for Windows Software 25You can also move between dilutions (bottles) without going th

Seite 23 - 5.8 ADD A SAMPLE TO THE BATCH

iCONTENTSSECTION 1 INTRODUCTION...11.

Seite 24 - 5.12 FIELD DESCRIPTIONS

Taking Initial DO Readings Section 6YSI Incorporated BOD Analyst for Windows Software 26You do not have to do the final DOs in the same order as you d

Seite 25 - 5.13 COLUMN DESCRIPTIONS

Taking Initial DO Readings Section 6YSI Incorporated BOD Analyst for Windows Software 27The fastest and easiest way is to set Technique: to auto. Aft

Seite 26 - 5.14 DELETING A BOTTLE

Taking Initial DO Readings Section 6YSI Incorporated BOD Analyst for Windows Software 28Now, we will want to measure only one of the dilutions of the

Seite 27 - 6.1 ENTERING BOTTLE NUMBERS

Taking Initial DO Readings Section 6YSI Incorporated BOD Analyst for Windows Software 29You don't have to derive initial DOs for every Sample in

Seite 28

SECTION 7 TAKING FINAL DO READINGS7.1 SELECTING A BATCHFrom the main bench sheet window, simply enter the sample date for the batch you would like tot

Seite 29 - 6.1.2 USING THE BARCODE WAND

Taking Final Dos Readings Section 7YSI Incorporated BOD Analyst for Windows Software 31Your Technique for Auto Stabilize setting affects how the BOD A

Seite 30 - 6.2 AUTO STABILIZATION

Taking Final Dos Readings Section 7YSI Incorporated BOD Analyst for Windows Software 327.3 CORRECTING MISTAKESIf you have finished reading the final D

Seite 31 - 6.4 DERIVED INITIAL DOS

SECTION 8 REPORTSUnder the File menu, you will find the Print Daily Bench Sheet and Print Everything Reportoptions. The Print Daily Bench Sheet will p

Seite 32

Reports Section 8YSI Incorporated BOD Analyst for Windows Software 348.1 REPORT DESIGNThe report designer is used to setup spreadsheet type reports.

Seite 33 - 6.5 CORRECTING MISTAKES

Reports Section 8YSI Incorporated BOD Analyst for Windows Software 35Key ActionUp Arrow Move up one rowDown Arrow Move down one rowRight Arrow Move ri

Seite 34 - 7.1 SELECTING A BATCH

ii7.3 CORRECTING MISTAKES...32SECTION

Seite 35

Reports Section 8YSI Incorporated BOD Analyst for Windows Software 36Note:To resize multiple columns at one time, select all the columns by clicking a

Seite 36 - 7.3 CORRECTING MISTAKES

Reports Section 8YSI Incorporated BOD Analyst for Windows Software 373. Release the left mouse button when the pointer is over the new location for th

Seite 37 - SECTION 8 REPORTS

Reports Section 8YSI Incorporated BOD Analyst for Windows Software 38ABS(A1)The absolute value of the cell is returned.ISEMPTY(A1)If A1 is empty then

Seite 38 - 8.1 REPORT DESIGN

Reports Section 8YSI Incorporated BOD Analyst for Windows Software 39Offset The offset from the start date of the report. For example, if the start

Seite 39

Reports Section 8YSI Incorporated BOD Analyst for Windows Software 408.1.9 MONTHLY FUNCTIONSMonthly functions return summary values for a sample for a

Seite 40 - 8.1.5 MOVING DATA

Reports Section 8YSI Incorporated BOD Analyst for Windows Software 41The ‘<<< Blank Report >>> selection loads a completely blank

Seite 41 - 8.1.7 FUNCTIONS IN FORMULAS

Reports Section 8YSI Incorporated BOD Analyst for Windows Software 428.2 EDIT MENU FUNCTIONSTo cut numbers, data values or text within the currently s

Seite 42 - 8.1.7 IF STATEMENTS

Reports Section 8YSI Incorporated BOD Analyst for Windows Software 43The Locate Sample Formula dialog can also be opened by clicking on the Locate Sam

Seite 43

Reports Section 8YSI Incorporated BOD Analyst for Windows Software 44Sample Name: Check the sample name box to have the sample name appear as a column

Seite 44 - 8.1.9 MONTHLY FUNCTIONS

Reports Section 8YSI Incorporated BOD Analyst for Windows Software 45Display [X] Decimal Places: Enter the number of digits to be displayed after the

Seite 45

SECTION 1 INTRODUCTIONBOD Analyst software ™ for Windows™ (BOD Analyst software) is a Windows-based PCsoftware accessory to the YSI 5000 and 5100 Diss

Seite 46 - LOCATING DATA ON THE REPORT

Reports Section 8YSI Incorporated BOD Analyst for Windows Software 46Statistic: Sets the summary statistic to use.Decimal Places: The number of digits

Seite 47

Reports Section 8YSI Incorporated BOD Analyst for Windows Software 478.4 FORMATTING CELLSThe BOD Analyst software Report Designer offers great flexibi

Seite 48

Reports Section 8YSI Incorporated BOD Analyst for Windows Software 488.5 OBTAINING HELP WHILE DESIGNING REPORTSThe help menu provides access to contex

Seite 49

SECTION 9 KEEPING YOUR DATA SAFE9.1 DATEThe BOD Analyst software depends on the correct date to do its calculations and manage thedata. The current d

Seite 50

Keeping Your Data Safe Section 9YSI Incorporated BOD Analyst for Windows Software 50will be created and opened. You must setup your samples and group

Seite 51 - 8.4 FORMATTING CELLS

SECTION 10 GRAPHING10.1 INTRODUCTIONThe graphing function provides the ability to produce time series type (Data vs. Time) graphs.Up to two samples ma

Seite 52 - 8.6 PRINTING REPORTS

Graphing Section 10YSI Incorporated BOD Analyst for Windows Software 52Sample 1 and Sample 2 are the fields in which the sample names are selected. If

Seite 53 - 9.3 UNDERSTANDING DATA FILES

Graphing Section 10YSI Incorporated BOD Analyst for Windows Software 53differences between printing in color or black and white.10.4 GETTING STATISTIC

Seite 54 - 9.5 REPAIR

SECTION 11 CUSTOMIZING YOUR PROGRAMThe BOD Analyst software is flexible enough to handle the wide variety of ways that people dotheir BODs. Some thing

Seite 55 - SECTION 10 GRAPHING

Customizing Your Program Section 11YSI Incorporated BOD Analyst for Windows Software 55number.The auto-stable routine starts immediately after the bot

Seite 56 - 10.3 PRINTING A GRAPH

Introduction Section 1YSI Incorporated BOD Analyst for Windows Software 2Click OK to proceed.The installation program will then display the following

Seite 57

Customizing Your Program Section 11YSI Incorporated BOD Analyst for Windows Software 56Maximum acceptable value for Initial DO minus Final DO in the d

Seite 58 - 11.2 AUTO-STABILIZATION

Customizing Your Program Section 11YSI Incorporated BOD Analyst for Windows Software 57The maximum acceptable value of BOD for tests with the sample n

Seite 59 - 11.3 THE CRITERIA FORM

Customizing Your Program Section 11YSI Incorporated BOD Analyst for Windows Software 58want the program to derive. You must measure at least one dilu

Seite 60

Customizing Your Program Section 11YSI Incorporated BOD Analyst for Windows Software 59Technique: This field describes exactly how and when a stable r

Seite 61

Customizing Your Program Section 11YSI Incorporated BOD Analyst for Windows Software 60Initial low temp: If the temperature of your initial DO is belo

Seite 62 - 11.5 THE YSI PARAMETERS FORM

Customizing Your Program Section 11YSI Incorporated BOD Analyst for Windows Software 61Comm port: The program can communicate to the YSI 5000/5100 DO

Seite 63

Customizing Your Program Section 11YSI Incorporated BOD Analyst for Windows Software 62Use Serial Number: Sets whether the program will assign Seria

Seite 64

Customizing Your Program Section 11YSI Incorporated BOD Analyst for Windows Software 63Serial Number forRAW 10 bottle

Seite 65 - 11.7 SERIAL NUMBERS

SECTION 12 CONTACT INFORMATIONFor any questions regarding PC6000 software, or any YSI equipment, please contact YSITechnical Support at (800) 897-4151

Seite 66

SECTION 13 ACCESSORIESINSTRUMENTS! 5000-115 Oxygen Instrument, Digital, Lab-115V! 5100-115 Oxygen Instrument, Digital, Lab with SOUR software – 115VPR

Seite 67 - RAW 10 bottle

Introduction Section 1YSI Incorporated BOD Analyst for Windows Software 3The Bench sheet is the main form of the BOD Analyst software. From the bench

Seite 68

1700/1725 Brannum LaneYellow Springs, Ohio 45387 USA(800) 765-4974 (937) 767-7241FAX: (937) 767-9320Website: http://www.ysi.comE-mail: [email protected]

Seite 69 - SECTION 13 ACCESSORIES

Introduction Section 1YSI Incorporated BOD Analyst for Windows Software 4Volume of bottles (ml) 300Dilution Unit mlSeed Added to BottleReport Font Ari

Seite 70

Introduction Section 1YSI Incorporated BOD Analyst for Windows Software 5Coefficient of Variation Limit 0.35Apply Criteria after Final Readings OnStep

Kommentare zu diesen Handbüchern

Keine Kommentare